“This one stayed on the bus side of a charger. The other half of the same problem is the AC side, where the PFC stage sets a different ripple spectrum and a different failure mode, and where the capacitor bank competes with the grid harmonics requirement rather than with the battery.”
In our previous analysis of charger capacitor banks and series stacks, we worked through voltage sharing, derating and balance loss on the DC bus. That bank is selected to match the battery and the isolated DC-DC stage. Move to the front end of the same cabinet and every rule changes, because a PFC capacitor on the AC side of a charger is sized to match the grid. Compare the two bills of materials and the AC-side power factor correction (PFC) output bank sits an order of magnitude higher in capacitance, on the same throughput power. What drives that is not the kilowatt rating. It is that the dominant ripple drops from tens of kilohertz to twice the line frequency, which turns a filtering job into a bulk 100 Hz energy storage problem.
Why the PFC Capacitor on the AC Side of a Charger Is Sized in Millifarads
Sizing starts with the energy balance between the pulsating line and the constant-power DC-DC stage. A single-phase active PFC forces the input current to track the sinusoidal grid voltage in phase, so instantaneous power follows sin2(ωt) and pulsates at twice line frequency: 100 Hz on a 50 Hz grid, 120 Hz on 60 Hz. On a 50 Hz system the input power swings from zero to twice the average and back twice every 20 ms, while the isolated converter feeding the battery demands a flat, continuous flow. The PFC output bank absorbs the surplus when instantaneous AC power exceeds average and returns it as the line voltage crosses zero.

The energy pulse (ΔE) transferred into and out of the PFC capacitor bank during each half-line cycle is governed by throughput power (P) and grid angular frequency (ω = 2π × fgrid):
ΔE = P / (2ω)
Consider a 50 kW charger module operating on a 50 Hz utility grid. The grid angular frequency is ω = 2 × 3.1416 × 50 = 314 rad/s, which gives 2ω = 628 rad/s. Substituting those values into the energy equation yields:
- 50 Hz Grid Energy Buffer (50 kW): ΔE = 50,000 / 628 = 79.6 J
- 60 Hz Grid Energy Buffer (50 kW): With ω = 377 rad/s and 2ω = 754 rad/s, ΔE = 50,000 / 754 = 66.3 J (for the exact same 50 kW charger, a 60 Hz grid requires 17% less buffered energy)
As those 79.6 J cycle in and out at 100 Hz, the bus voltage rises and falls around its regulated level. Throughout this guide, voltage fluctuation is given as peak ripple (ΔVpeak, from nominal to either peak); peak-to-peak (ΔVpp) is exactly twice that. For a small ripple fraction on a nominal bus V:
ΔV_peak ≈ ΔE / (C × V)
On an 800 V PFC bus buffering 79.6 J at 50 Hz, increasing capacitance brings the voltage swing down along an inverse curve:
| PFC Output Capacitance (C) | Peak Ripple ΔVpeak (50 Hz, 79.6 J) | Peak-to-Peak Ripple ΔVpp |
|---|---|---|
| 1000 µF | 99.5 V | 199 V |
| 2200 µF | 45.2 V | 90.5 V |
| 4700 µF | 21.2 V | 42.3 V |
| 4975 µF | 20.0 V | 40.0 V |

To hold peak ripple voltage to 20.0 V (40.0 V peak-to-peak) on a 50 kW charger, the AC side requires approximately 5 mF at 800 V. This value is not an arbitrary safety margin. The AC-side bank sits an order of magnitude above the DC-link filter because 2ω sits at 628 rad/s instead of 300,000 rad/s.
PFC output sizing is bounded by three concurrent constraints: hold-up time during dropouts, low-frequency ripple voltage, and ripple current rating. Engineers often assume hold-up always dominates, but the two usually land close together. Infineon’s CCM boost PFC design guide gives a checkable 1200 W benchmark: 400 V nominal, 340 V minimum during dropout, 60 Hz line, 16.6 ms hold-up target, and a 10 V peak-to-peak ripple limit. Minimum capacitance for each constraint comes out as:
- By 16.6 ms hold-up time: 900.9 µF
- By 10 V peak-to-peak (5 V peak) ripple voltage: 795.8 µF
The two figures sit within 13% of each other, so the designer takes 900.9 µF and builds it from two 560 µF / 450 V aluminum electrolytics in parallel. The surprise comes in the thermal check: a dissipation factor (DF) of 0.2 works out to 0.237 Ω ESR, and at 6.47 A rms those two cans shed 9.91 W of ohmic heat. Capacitance takes two equations. Getting 10 W out of two capacitor cans is what sets the layout.
How 100 Hz Ripple Current Hits Aluminum Electrolytic ESR at Its Worst Point
With the bank fixed at 4.975 mF, the 79.6 J pulse appears as a peak ripple of 20.0 V, which is 40.0 V peak-to-peak. The next question is how much low-frequency current that swing drives through the dielectric and electrolyte. For a sinusoidal 100 Hz ripple of ΔVpp = 40 V, the voltage changes fastest at the zero crossings:
dV/dt|peak = π × 100 × 40 = 12566 V/s
Multiplying that slew rate by the 4.975 mF capacitance gives the peak and RMS 100 Hz capacitor currents:
- Peak 100 Hz Ripple Current: Ipeak = C × dV/dt = 4.975 × 10-3 × 12566 = 62.5 A
- RMS 100 Hz Ripple Current: Irms = 62.5 / √2 = 44.2 A
Compare 44.2 A rms against the steady-state DC load of the same charger at 800 V: 50,000 / 800 = 62.5 A. The 100 Hz ripple equals 70% of the full DC output current, and all of it lands at the frequency where an aluminum electrolytic is weakest, because wet electrolyte ion mobility limits conductivity at low frequency. ESR peaks right at 100 Hz to 120 Hz.
Because single aluminum electrolytic cells top out around 450 V to 500 V in mass-produced snap-in and screw-terminal packages, an 800 V bus requires series pairs. To build the 4.975 mF / 800 V bank using standard 2200 µF / 400 V cells, connecting two 2200 µF units in series yields 1100 µF at 800 V per string. Reaching 4.975 mF theoretically takes 4.5 parallel strings (9 capacitors), which hardware engineers round up to 5 parallel strings (10 capacitors) to keep every series pair symmetrical. Evaluating thermal stress at the 4.5-string design point shows that each string carries 44.2 / 4.5 = 9.8 A rms. Using a low-ESR industrial cell with an ESR of 30 mΩ (0.03 Ω) at 100 Hz, each capacitor dissipates:
P_loss = 9.82 × 0.03 = 2.9 W per capacitor
Across the bank, that adds up to roughly 26 W at nine capacitors and 29 W at ten of continuous low-frequency heat before accounting for high-frequency switching ripple. Compare that with the 1200 W Infineon reference design, where a DF of 0.2 produces 0.237 Ω of ESR and 9.91 W of capacitor heat at 6.47 A rms. Low-frequency ESR is the thermal bottleneck in both cases. When engineers size PCS DC-link capacitors and ripple current filters on the high-frequency inverter side, they apply frequency multiplier tables to take advantage of lower ESR above 10 kHz. On the AC-side PFC stage, the base 100 Hz rating governs survival directly.
| Design Dimension | AC-Side PFC Output Bank | DC-Side Bus / Output Bank |
|---|---|---|
| Dominant Ripple Frequency | 100 Hz / 120 Hz (2ω line frequency) plus switching harmonic | 20 kHz to 100 kHz (converter switching frequency) |
| Voltage Ripple Amplitude | Large (ΔVpeak of 10 V to 25 V on an 800 V bus) | Small (ΔVpeak typically under 2 V to 5 V) |
| Governing Sizing Parameter | Bulk capacitance (mF) for 2ω energy buffer and 100 Hz ESR | High-frequency ripple current rating and frequency multiplier |
| Primary Failure Mode | Core heating from 100 Hz I2R loss and grid surge overvoltage | High-frequency skin-effect heating and series voltage imbalance |
Interleaving is the architectural lever. Split the boost stage into two or more phase legs with phase-shifted gate signals and the inductor ripple currents cancel at the common output node. The high-frequency share of the RMS current entering the bank drops, so the electrolytics can spend their thermal budget on the 100 Hz pulse they cannot avoid.
Why Grid Harmonics Standards Constrain Bus Ripple Bandwidth
A common misreading of power supply specifications treats the PFC output capacitor as the part that filters line harmonics for IEC 61000-3-2 (equipment up to 16 A per phase) or IEC 61000-3-12 (16 A to 75 A). It cannot. A capacitor behind the boost diodes does not shape the input waveform; the PFC current loop enforces the harmonic limits.
Yet the bank decides whether that loop can do its job. A PFC controller runs two nested loops: a fast inner current loop shaping the input current to the rectified line voltage, and a slow outer voltage loop regulating the 800 V average. That bus carries 100 Hz ripple, and the ripple feeds straight into the outer error amplifier. If the outer loop responds to it, the inner reference is modulated at 100 Hz, and a 50 Hz reference multiplied by a 100 Hz term produces a 150 Hz third harmonic in the line current. That is how a charger fails IEC 61000-3-2 or 3-12 compliance.
To avoid it, control engineers roll the outer loop off below 10 Hz to 20 Hz, which leaves the inner loop and the power stage dependent on passive capacitance to hold the bus over each 10 ms half cycle. The ripple window is also a duty-cycle margin: swing too high and the boost trips overvoltage protection, dip too low and it loses the headroom above the AC peak it needs to control inductor di/dt. The ripple spec is a control-stability requirement, not an EMI target. The same interaction appears when designing capacitors for 800 V on-board chargers.
Three Grid-Side Stresses That Do Not Exist on the Battery Bus
The PFC stage sits directly behind the EMI filter at the service entrance, so its bank sees field stresses the battery-side bank never does:
- Surges from lightning and grid switching. The AC input is the only port connected straight to the distribution grid. When a nearby strike or a utility capacitor bank switching event sends an 8/20 µs surge down the line, part of it passes the front-end MOVs and travels through the boost diode into the bulk bank. Cells with a verified surge rating, 450 V surge on a 400 V part or 500 V on a 450 V part, keep the dielectric oxide intact through a line swell.
- Sags and repeated soft-start inrush. Commercial grids sag and reclosers cycle. Every recovery runs the charger through pre-charge and PFC soft start, and a 5 mF bank at 800 V holds about 1,600 J at full bus voltage. Repeated recharge cycles load the capacitor tabs, internal foil welds and pre-charge relays with heavy repetitive current pulses.
- Regional grid frequency. One hardware platform gets certified for both 50 Hz and 60 Hz exports. As the energy calc shows, dropping from 60 Hz to 50 Hz raises the per-half-cycle pulse by 17% at the same 50 kW. Utilities also allow small deviations during load imbalance, such as 49.0 to 49.5 Hz. A bank sized on a 60 Hz bench will see higher ripple and hotter cores on a 50 Hz feed.
Choosing Between Aluminum Electrolytic and Film Capacitors in the PFC Stage
Specifying the 800 V PFC output stage comes down to assigning each dielectric to the band it handles, rather than picking one as a universal replacement for the other:
- Aluminum electrolytic for the bulk 100 Hz buffer. Buffering 79.6 J at 800 V with a 20.0 V peak ceiling needs about 5 mF, and reaching 5 mF at 800 V in film would take an enclosure bigger and costlier than the whole PFC module. High-voltage snap-in and screw-terminal parts such as the Xuansn XLW series at 105 °C pack 4.975 mF to 5.5 mF into a compact footprint. The engineering work is managing 100 Hz ESR heat through string distribution and forced-air or cold-plate coupling. Our aluminum electrolytic capacitor selection guide covers the construction types.
- Film for high-frequency decoupling and surge absorption. Metallized film offers far less capacitance per cubic centimetre, so it cannot carry the sin2(ωt) swing alone. What it does offer is very low ESL, low ESR from 20 kHz to 100 kHz, and no electrolyte to evaporate.
- The hybrid most production chargers use. Both families sit in parallel across the 800 V rail. The electrolytic bank, typically five parallel strings of series-connected 2200 µF / 400 V or 4700 µF / 400 V Xuansn cells, absorbs the 100 Hz pulse and meets hold-up. A small film or ceramic bank a few millimetres from the SiC MOSFET and diode bridge handles the switching di/dt loops and fast transients.
Frequently Asked Questions
How do I size the PFC output capacitor for a charger?
Calculate capacitance under three separate constraints and take the largest: the 2ω energy ripple (C ≈ ΔE / (V × ΔVpeak), with ΔE = P / 2ω), hold-up time during an AC dropout, and the 100 Hz RMS ripple current thermal limit. In a 1200 W / 400 V stage at 60 Hz, hold-up needs 900.9 µF against 795.8 µF for a 10 V peak-to-peak ripple limit, so you pick 900.9 µF (two 560 µF / 450 V in parallel) and then confirm the package can shed the 9.91 W of ESR heat.
Why is the AC-side capacitor so much larger than the DC-link one?
The AC-side bank buffers power at twice line frequency, 100 or 120 Hz, while the downstream DC-link filters at 20 kHz to 100 kHz. Required energy storage scales inversely with angular frequency, so dropping from tens of kilohertz to 100 Hz raises the capacitance by an order of magnitude and pushes a 50 kW / 800 V stage to roughly 5 mF.
Does the grid frequency change the capacitor size?
Yes. Buffered energy equals P / (2ω), so 50 Hz forces 79.6 J at 50 kW against 66.3 J on 60 Hz. That is 17% more capacitance for the same ripple, which is why a global platform is sized on the 50 Hz case.
Can I use film capacitors for the PFC stage?
Not for the bulk buffer. Several millifarads at 800 V in film takes excessive volume and cost. Pair an electrolytic bank for the 100 Hz swing and hold-up with small film capacitors close to the switches for the 20 kHz to 100 kHz currents.
Designing an 800 V PFC stage for a commercial charger and need verified 100 Hz ESR and ripple current data for your capacitor bank? Contact the Xuansn engineering team for datasheets, thermal modeling support, and custom sample kits: