A 350 kW charger runs its DC bus at around 800 V, and no single aluminium electrolytic capacitor is rated for that. The part you buy is a 450 V or a 500 V can. Everything between that can and the bus is series-connected, and the series connection is where a charger bank differs from the banks in the articles this site has already covered.

Ripple current decides how big the bank has to be. That part has not changed, and it is settled elsewhere. What this piece works through is the layer above it. Given the capacitance you need and the ripple current it has to survive, how many cans go in series, how far each one is derated, what the balancing resistors cost you in standing loss, and what happens to all of it when the charger is built from eight modules rather than one rectifier.

The Voltage You Have to Reach, and What It Costs

An 800 V bus with a 450 V capacitor means two in series at minimum, and two 450 V cans in series put each one at 400 V. That is 89 percent of its rating before any transient has arrived. Three 400 V parts at 1000 V land at 333 V each, which is 83 percent. Three 470 V parts at 1000 V come down to 74 percent but need more cans for the same capacitance.

Bus voltagePart ratingIn seriesVolts per canShare of rating
800 V450 V2400 V89%
800 V500 V2400 V80%
1000 V400 V3333 V83%
1000 V450 V3333 V74%

The 500 V part at 800 V is the cheapest way to gain margin without adding cans. It holds 9 percentage points more headroom than the 450 V option at the same series count. The difference matters because a charger bus is not quiet. Regenerative energy from a vehicle-side battery pushes the bus up, cable inductance at the moment the contactor closes adds a spike on top, and grid surge rides in on all of it. Each event lasts a few hundred microseconds and each one counts against the rating.

Series connection also divides capacitance. Two 2200 µF cans in series give 1100 µF and twice the ESR of one can. Below about 1000 µF on an 800 V bus, parallel strings stop being optional.

Balancing Resistors Are Not a Safety Item, They Are a Design Constraint

Two capacitors in series do not share voltage equally. Leakage current varies from part to part, and the can with the lower leakage drifts to a higher voltage until something limits it. An equalising resistor across each can does that limiting, and the temptation is to size it once, generously, and forget it.

The resistor current has to be several times the worst-case leakage difference, which puts the standing loss directly at the mercy of the leakage specification you accepted. Take a 2200 µF 450 V can. Its leakage limit works out to about 3 mA. At ten times leakage the resistor passes 30 mA, and against 400 V per can that is roughly 12 W burned continuously in each resistor.

Schematic of two charger capacitor bank cans in series across an 800 V DC bus with a 13 kOhm balancing resistor across each can

Scale it to a real charger. Eight power modules, eight cans each, is 64 cans. At 12 W apiece the balancing network alone draws about 760 W with the charger idle. Over a year at 8760 hours that is roughly 6700 kWh, and at industrial rates it is a four-figure annual bill for a circuit that does nothing but hold two voltages equal.

ConfigurationPer-can voltageLeakage limitResistor at 10x leakage64-can standing loss
2200 µF 450 V, 2 in series400 V3.0 mA13 kΩ, 11.9 W764 W
1000 µF 500 V, 2 in series400 V2.1 mA19 kΩ, 8.5 W543 W
1000 µF 400 V, 3 in series333 V1.9 mA18 kΩ, 6.3 W405 W
10000 µF 350 V, 3 in series267 V5.6 mA5 kΩ, 15.0 W958 W

Read the last two columns together and the counterintuitive part shows up. Bigger cans are not better here. The 10000 µF 350 V part reaches the same capacitance with fewer cans, and then costs 958 W of standing loss because its leakage allowance scales with capacitance as much as it does with voltage. The 1000 µF 400 V configuration, three in series at 1000 V, costs less than half that.

This is the trade a charger designer makes. Capacitance per can means fewer parts and a simpler busbar. It also means a bigger leakage allowance per can, and the balancing network has to overdrive it. On a charger that sits idle overnight and delivers a few hundred kWh a day, the idle loss is an operating cost, not a datasheet footnote.

Why the Module Count Decides More Than the Capacitance

Nothing at 350 kW is built as one converter. A charger is a rack of modules in parallel, and the module count changes what each capacitor bank has to do.

At eight modules, a 350 kW charger puts about 44 kW in each one, which on an 800 V bus is roughly 55 A per module. Six modules raise that to 73 A. The same eight-module architecture scaled to a megawatt puts 125 kW and 156 A in each module, which is where the module design has to change rather than the capacitor.

The module count also sets the failure arithmetic. Eight modules with one offline leaves the remaining seven carrying 14 percent more each. Six modules with one offline leaves 20 percent more. Sixteen modules with one gone leaves only 7 percent more, and for a charger that has to keep serving while a module is swapped, that headroom counts. It is also why a charger rated 350 kW is often built from modules that can each deliver slightly more than 350 divided by the number fitted.

What the Ripple Current Does to a Series String

A series string is a single current path, so the same ripple current flows through every can in it regardless of how the capacitance is divided. That looks harmless until you check the resonance. Series capacitance is lower than any single can and ESR is higher, which pushes the bank’s self-resonant frequency down. A bank that was well-behaved as one 2200 µF part can sit on the inductive side of resonance at the switching frequency once it becomes two 2200 µF parts in series.

The fix is usually more parallel strings, not bigger cans. Four parallel strings of two in series brings the ESR down by a factor of four and the ripple heating with it, which is why the charger banks in service look like a wall of cans rather than a handful of large ones.

Rows of XLW 10000uF 350V aluminum electrolytic capacitors bolted to copper busbars in a DC fast charger cabinet
The ripple current calculation for a DC-link bank carries over directly. What does not carry over is the assumption that bigger capacitance is the answer, because in a series string it is the wrong lever.

The Ambient Is Not What the Datasheet Measured

A charger cabinet in summer is not 25 °C inside. The power modules are the heat source, the cabinet is sealed against weather, and the capacitor bank usually sits downstream of the airflow that cools the switching devices. A 105 °C can at 105 °C is at end of life, not at the edge of a margin.

Two cans in a string make this worse in a subtle way. They do not share temperature, because one sits closer to the heatsink or the exhaust than the other. The hotter can leaks more, which shifts the voltage division toward the cooler one, which then runs at higher voltage and higher loss. The equalising resistors cap how far this drifts, but the drift is there regardless, and it is one more reason the resistor current cannot be sized at the bare minimum.

A 450 V part at 400 V is 89 percent of rating. Running a can at 89 percent while it is also 20 °C hotter than the datasheet ambient is where the lifetime margin goes. Stepping up to a 500 V part derates it to 80 percent in exchange for a larger can.

What to Put on the Specification

A charger bank specification has to state the series count and the balancing scheme, because the supplier of the capacitors cannot infer either from a capacitance and a voltage.

Line itemWhy it has to be explicit
Bus voltage, nominal and maximumThe maximum, not the nominal, sets the series count
Series count and parallel stringsDetermines capacitance per can and bank ESR
Volts per can at maximum busThe derating figure the warranty argument rests on
Rated ripple current and frequencyRipple rating is frequency dependent, one number is not enough
Ambient at the can, not at the cabinet doorThe difference can be 20 °C or more
Balancing method and resistor currentSets the required leakage limit and the standing loss budget

Xuansn builds the screw-terminal and snap-in ranges that these banks use, in the 200 V to 500 V span where charger strings are assembled, and can supply the leakage and ripple figures per can so the balancing network can be sized against a real number rather than a catalogue maximum. The 6800 µF 200 V screw-terminal part is an example of the construction used where four cans go in series for an 800 V string.

Where the Next Piece Goes

This one stayed on the bus side of a charger. The other half of the same problem is the AC side, where the PFC stage sets a different ripple spectrum and a different failure mode, and where the capacitor bank competes with the grid harmonics requirement rather than with the battery. That is the piece this series picks up next.

Common Questions About Charger Capacitor Banks

Can one 800 V capacitor replace two 450 V parts in series?

If one exists with the capacitance and ripple rating you need, it removes the balancing network and its standing loss entirely, and it removes the voltage sharing question along with it. The 800 V class exists in aluminium electrolytic, though the capacitance range is narrower than at 450 V, and the price per microfarad is higher. Whether it wins depends on how much capacitance the ripple current actually demands.

How much margin should a charger capacitor have?

Eighty percent of rated voltage at the maximum bus voltage is a common target, with the part chosen so that the maximum bus under surge still stays inside the rating. That usually means a 500 V part for an 800 V bus rather than a 450 V one, because the two-in-series arrangement puts either at 400 V and only one of them has margin left for the surge.

Do balancing resistors still matter if the capacitors are from one production batch?

Yes, and more than the batch argument suggests. Leakage current drifts with temperature and with age, and two cans in the same string do not sit at the same temperature. The resistor has to cover the drift over life, not the spread at the moment of assembly, which is why sizing at two or three times the initial leakage is thin.

Is a film capacitor a better answer for a charger DC link?

Film handles ripple current better per unit volume at high frequency and does not have the electrolyte evaporation failure mode, which is why some charger designs use film for the bulk of the ripple and electrolytic or ceramic only where the capacitance per unit cost matters. The series-voltage problem disappears too, since film DC-link parts are available above 1000 V. What film does not do is deliver thousands of microfarads at a price a charger bill of materials can absorb.

Designing a charger bank and need the leakage and ripple figures per can? Send Xuansn the bus voltage, the series and parallel arrangement you are considering, the ripple current with its frequency, and the ambient at the can. Our engineers will come back with the derating figure, the leakage allowance to size the balancing network against, and the part that fits. Reach us at coco@xuanxcapacitors.com, call +86-769-8166 8821, or send the specification through the contact page.